Specifier Tool

PowerEstimator

Calculate electrical load, running costs, heat output, and infrastructure requirements for any LED display.

4
2.5
SMD — Max 360 W/sqm
70%
12h
Power Consumption
Display Area
10.0
4m × 2.5m
Max Power
3.6kW
3,600W full white
Avg Power
0.9kW
910W at 70%
Daily Usage
10.9kWh
12 hours/day
Running Costs (UAE (DEWA/ADDC))
Monthly
AED 95
328 kWh/month
Annual
AED 1,156
3986 kWh/year
CO2 / Year
1.6tons
GCC grid average
MEP Specifications
Max Current
16.4A
At 220V single phase
Breaker Size
25A
Including 25% safety margin
Cable Size
2.5mm²
Recommended minimum
Heat Output
12,283BTU/h
1.0 tons cooling
GCC Climate Note: LED displays generate 1.0 tons of heat load that must be offset by HVAC. For outdoor installations, add 30-40% additional cooling capacity.

Power Consumption by Pixel Pitch

PitchMax W/sqmAvg W/sqm10sqm Max kW10sqm Heat BTU/hTechnology
P0.96202206.2 kW21,154COB MicroLED
P1.25501955.5 kW18,766COB / MiP
P1.54801704.8 kW16,378MiP / SMD
P1.94201504.2 kW14,330MiP / SMD
P2.53601303.6 kW12,283SMD
P3.93001103.0 kW10,236SMD
P4.82801002.8 kW9,554SMD
P64501604.5 kW15,354SMD Outdoor
P85001805.0 kW17,060SMD Outdoor
P105502005.5 kW18,766SMD Outdoor
P166002206.0 kW20,472SMD Outdoor

Power-Saving Tips

Smart Brightness Scheduling

Reduce brightness during low-traffic hours. Saves 30-50% on electricity.

Ambient Light Sensors

Auto-dim based on room lighting conditions.

Content Optimization

Dark-themed content consumes significantly less power.

Scheduled Power-Off

Turn off displays during non-business hours.

Frequently Asked Questions

A typical indoor P2.5 LED display consumes 130-360 W/sqm (average to maximum). A 10 sqm display running 12 hours daily costs approximately AED 115/month in the UAE.
Maximum power is drawn when all LEDs display full white at full brightness. Average power (typically 30-40% of max) represents real-world content.
Yes, LED displays convert approximately 60-70% of electrical input into heat. A 10 sqm indoor display can generate 4,500-12,000 BTU/h of heat.
Circuit breaker sizing should be based on maximum power draw plus a 25% safety margin. Always consult a licensed electrician.